Download TDS

AH-C Low-Conductivity Aluminium Hydroxide

KELUM® Aluminium Hydroxide — Flame-Retardant Filler · CAS 21645-51-2 · Al(OH)₃ · M.W. 78.00
1.50–1.75 µmMedian d50
≤50 µS/cmConductivity
≥99.5%Whiteness
Product Grade · AH-C
Bayer Process · Ultrafine Precipitation
Grade Family: AH Series
Hanzhong Delike New Materials Co., Ltd.
Section 1 · Overview

Grade Overview

AH-C is KELUM®’s low-conductivity grade, engineered specifically for electrical insulation. With a 10% slurry conductivity of ≤50 µS/cm, soluble Na₂O ≤0.15% and Fe₂O₃ ≤0.006%, it carries the lowest ionic impurity level in the AH series — the factor that governs leakage current and insulation resistance in wet or humid service.

Soluble sodium salts are the main cause of surface leakage in polymer insulation; AH-C is deep-washed during production to strip them well below standard-grade levels. The d50 of 1.50–1.75 µm maintains excellent dispersion in high-loading HFFR compounds, while the 45 µm sieve residue of ≤0.01% eliminates pinhole risk in thin insulation walls.

Whiteness ≥99.5% keeps white and pastel cable jackets clean and bright. AH-C is the grade of choice for medium- and high-voltage HFFR insulation, XLPE compounds, copper-clad laminates and electronic encapsulation resins where electrical integrity is non-negotiable.

Section 2 · Technical Data

Technical Specification

Full specification from the production TDS for AH-C. Values are lot-average; a Certificate of Analysis (COA) accompanies every commercial shipment.

ParameterSpecification
Al(OH)₃ Purity≥99.6%
Moisture (105°C)≤0.30%
Loss on Ignition34.5 ± 0.5%
Soluble Na₂O≤0.15%
Fe₂O₃≤0.006%
SiO₂≤0.012%
Conductivity (10% slurry)≤50 µS/cm
Whiteness (R457)≥99.5%
Residue on 45 µm sieve≤0.01%
Median Particle Size (d50)1.50–1.75 µm
Oil Absorption24–30 ml/100g

Test methods: purity & impurities by chemical analysis; whiteness R457 blue-light reflectance; conductivity measured on 10% aqueous slurry at 25°C; particle size by laser diffraction (Malvern Mastersizer); residue by wet sieving on 45 µm screen. Packaging: 25 kg PE-lined kraft paper bags, 1000 kg FIBC on request. MOQ: 1 metric ton.

Section 3 · Applications

Typical Applications

✓

MV / HV Cable Insulation

HFFR EVA/POE insulation compounds for medium- and high-voltage power cable where low leakage current is mandatory.

✓

XLPE Compounds

Cross-linked polyethylene insulation with maximum long-term insulation resistance.

✓

Electronic Insulation Parts

Connectors, sockets, terminal blocks and switch housings requiring stable electrical properties.

✓

Copper-Clad Laminates

Electronic-grade filler for CCL and printed-circuit board materials.

✓

Wet-Environment Wire & Cable

Cables for damp, humid or underground service where ionic migration causes tracking failures.

✓

Encapsulation Resins

Epoxy / polyurethane potting compounds for transformers, sensors and power modules.

Section 4 · Selection

Grade Selection Guidance

When to choose AH-C:

AH Series Quick Comparison
ParameterAH-A
Ultrafine
AH-B
Standard
AH-C
Low Cond.You are here
AH-SM
Surface Mod.
Median Particle Size d501.20–1.35 µm1.35–1.50 µm1.50–1.75 µm1.20–1.80 µm
Whiteness (R457)≥99.5%≥99.0%≥99.5%≥99.0%
Conductivity≤80 µS/cm≤100 µS/cm≤50 µS/cm≤100 µS/cm
Soluble Na₂O≤0.20%≤0.25%≤0.15%≤0.25%
Oil Absorption20–25 ml/100g22–28 ml/100g24–30 ml/100g16–22 ml/100g
Residue 45 µm≤0.01%≤0.02%≤0.01%≤0.02%
Section 5 · Related

Related Grades & Resources

Explore the other grades in the KELUM® AH series, download the complete technical documentation, or request a production-line sample for evaluation.

Frequently asked questions

What makes AH-C low-conductivity?

AH-C is washed and classified to keep soluble ionic species low, which matters for cable insulation and electronic packaging.

Which applications need AH-C?

LV/MV cable insulation, electronic potting and any compound where ionic conductivity is measured.

What particle size does AH-C have?

d50 1.50–1.75 µm, Al(OH)₃ ≥99.6 %.