KELUM® Aluminium Hydroxide [Al(OH)â] is a halogen-free, environmentally friendly inorganic flame retardant that functions through an endothermic decomposition mechanism. When exposed to heat in the range of 250–350 °C, Al(OH)â undergoes thermal decomposition, absorbing a significant amount of energy (approx. 1,050 J/g) from the combustion zone. This endothermic reaction cools the substrate below its ignition temperature, effectively suppressing flame propagation.
The released water vapor (HâO) serves three critical functions simultaneously: (1) it dilutes combustible gases in the flame zone, reducing the concentration of flammable volatile compounds; (2) it forms a protective steam blanket that displaces oxygen from the polymer surface; and (3) the residual alumina (AlâOâ) creates a thermally stable, insulating char layer that acts as a barrier to heat and mass transfer. Unlike halogenated flame retardants, KELUM® Al(OH)â generates no toxic or corrosive gases, produces extremely low smoke, and leaves no hazardous decomposition products — making it the preferred choice for low-smoke, zero-halogen (LSZH) cable compounds, construction materials, and public-transport interior applications.
The flame retardant performance of KELUM® Al(OH)â in polymer matrices is evaluated according to the following internationally recognized test standards. Results are dependent on loading level, polymer matrix, and compound formulation.
| Test Standard | Full Name | Key Metrics | Description & Relevance | Typical KELUM® Result |
|---|---|---|---|---|
| UL 94 | Standard for Safety — Flammability of Plastic Materials | V-0 / V-1 / V-2 Rating | Vertical burn test measuring afterflame time, afterglow, and flaming drips. The most widely referenced plastics flammability standard worldwide. | V-0 (at ⥠60% loading in EVA/PE) |
| LOI ISO 4589 / ASTM D2863 |
Limiting Oxygen Index | Oâ % required to sustain combustion | Measures the minimum oxygen concentration in an Oâ/Nâ mixture that supports candle-like combustion. Higher values indicate better flame retardancy. Materials with LOI > 21% are considered "self-extinguishing" in air. | ⥠28% (neat KELUM® in EVA) |
| Cone Calorimeter ISO 5660 / ASTM E1354 |
Cone Calorimeter — Heat Release & Smoke | HRR, THR, SEA, TTI, MLR | Bench-scale fire test that measures heat release rate (HRR), total heat release (THR), specific extinction area (SEA / smoke), time to ignition (TTI), and mass loss rate (MLR) under a controlled radiant heat flux (typically 35 or 50 kW/m²). | pHRR reduced by 50–70% vs. unfilled polymer |
| TGA / DSC | Thermogravimetric Analysis / Differential Scanning Calorimetry | Tonset, Tpeak, ÎH, Residue | Thermal analysis techniques characterizing decomposition temperature, mass loss profile, and endothermic enthalpy. TGA quantifies decomposition steps; DSC measures the energy absorbed during the endothermic transition. | Tonset: 250 °C Tpeak: 300–320 °C ÎH: ~1,050 J/g |
HRR = Heat Release Rate (peak & average) | THR = Total Heat Release | SEA = Specific Extinction Area (smoke density) | TTI = Time to Ignition | MLR = Mass Loss Rate | Results are formulation-dependent. Contact our technical team for grade-specific data.
All flame retardant testing is conducted under controlled laboratory conditions in accordance with the applicable ISO, ASTM, and UL standards. Below are the standardized procedures for each test method.
The table below summarizes typical flame retardant performance results for KELUM® AH-A (ultrafine), AH-B (standard), and AH-C (low-conductivity) grades at 60 wt% loading in EVA, PE, and PVC matrices. All tests were conducted on compression-molded plaques (3.0 mm thickness) conditioned per applicable standards.
| KELUM® Grade | Matrix (60 wt%) | UL 94 Rating (3.0 mm) |
LOI (% Oâ) |
Peak HRR (kW/m² @ 35 kW/m²) |
THR (MJ/m²) |
SEA (avg.) (m²/kg) |
Tonset (°C, TGA) |
Char Residue (% @ 600°C) |
|---|---|---|---|---|---|---|---|---|
| AH-A (Ultrafine) | EVA (VA 28%) | V-0 | 29.5 | 185 | 62 | 210 | 252 | 38.5 |
| AH-A (Ultrafine) | LDPE | V-0 | 28.0 | 220 | 70 | 260 | 255 | 37.8 |
| AH-A (Ultrafine) | PVC (flexible) | V-0 | 32.0 | 155 | 48 | 175 | 248 | 40.2 |
| AH-B (Standard) | EVA (VA 28%) | V-0 | 28.5 | 210 | 68 | 240 | 250 | 38.0 |
| AH-B (Standard) | LDPE | V-0 | 27.5 | 250 | 76 | 290 | 253 | 37.5 |
| AH-B (Standard) | PVC (flexible) | V-0 | 31.0 | 170 | 52 | 195 | 247 | 39.8 |
| AH-C (Low Conductivity) | EVA (VA 28%) | V-0 | 29.0 | 195 | 65 | 225 | 251 | 38.2 |
| AH-C (Low Conductivity) | PE (XLPE cable) | V-0 | 28.2 | 215 | 71 | 245 | 254 | 37.9 |
Test conditions: Compression-molded 3.0 mm plaques. 60 wt% KELUM® loading unless otherwise noted. Cone data at 35 kW/m² irradiance, horizontal orientation. All values are typical and may vary with specific formulation (co-additives, processing conditions, specimen thickness). For grade-specific Certificates of Analysis (COA) or formulation optimization support, contact our technical team.
Key observations: AH-A (ultrafine d50 ~1.25 μm) consistently delivers the best balance of flame retardancy and smoke suppression due to superior dispersion in the polymer matrix. AH-C grade maintains flame performance while achieving < 50 μS/cm conductivity — essential for high-voltage cable insulation. All KELUM® grades achieve UL 94 V-0 at 60% loading with LOI values well above the 21% air threshold, confirming excellent self-extinguishing behavior.
Hanzhong Delike New Materials Co., Ltd. offers complimentary customer-specific flame retardant testing for qualified prospects and partners. Send us your base polymer (EVA, PE, PP, PVC, PA, rubber, epoxy, or others), and our in-house laboratory will:
Typical turnaround time is 5–7 business days from receipt of your resin sample. We also offer surface-modified grades (AH-SM) for enhanced compatibility and dispersion in polyolefins, engineering thermoplastics, and thermoset composites.